Idea Statica
  • Steel
  • Concrete
  • BIM & Workflows
  • Support & Learning
  • Pricing
  • Company
  • Steel overview
  • Connection design
  • Member design
  • Parametric design
  • Steel case studies
  • Concrete overview
  • Walls and D-regions
  • Anchoring design
  • Concrete case studies
  • BIM Overview
  • Supported integrations
  • Checkbot
  • Viewer
  • APIs
  • Support Center
  • E-learning & certification
  • Blog
  • Downloads & Licensing
  • Plans
  • Free community tool
  • Enterprise customers
  • Students & educators
  • How much will you save?
  • About us
  • Contact
  • Research & development
  • Authorized resellers
  • Meet our customers
  • Career
  • Steel
    Steel overviewConnection designMember designParametric designSteel case studies
  • Concrete
    Concrete overviewWalls and D-regionsAnchoring designConcrete case studies
  • BIM & Workflows
    BIM OverviewSupported integrationsCheckbotViewerAPIs
  • Support & Learning
    Support CenterE-learning & certificationBlogDownloads & Licensing
  • Pricing
    PlansFree community toolEnterprise customersStudents & educatorsHow much will you save?
  • Company
    About usContactResearch & developmentAuthorized resellersMeet our customersCareer
14-Day Trial
14-Day Trial

Subscribe to our newsletter

Company

  • About us
  • Partners
  • Careers
  • Patent

Resources

  • Customer projects
  • Case studies
  • Connection Library
  • Verification books

Legal

  • EULA
  • Global privacy policy
  • California Privacy
  • TOS Viewer
  • Licensing

Help

  • Contact
  • Quote request
  • Resellers
  • Downloads
FacebookInstagramLinkedInYouTube

© IDEA StatiCa 2009-2026

Trusted and used worldwide by engineers, fabricators & consultants.

Support CenterKnowledge Base ArticlesCode-check of bolts and preloaded bolts (EN)
Advanced analysis types for your steel structures
Bolts are too close to plate edge
Traffic lights for forces in bolts
Prying and high tension force in bolts
Bolt force distribution in end-plate beam-to-column connection
Bolt shear force calculated per shear plane
Through-bolts in hollow sections: design them as pins, not bolts
Bolt bearing distances for Eurocode
Warnings for welds and bolts connecting the same plates
Slip resistance check update according to SP 16
Detailing improvements for bolts and welds in Eurocode
Angle to the grain of the steel-to-timber connections
Filler plate (packing plate) recognition
Smooth results with precise meshing
Code-check of bolts and preloaded bolts (EN)
Code-check of bolts and preloaded bolts (AISC)
Code-check of bolts and preloaded bolts according to Canadian standards
Code-check of bolts and preloaded bolts according to Australian standards
Code-check of bolts and preloaded bolts according to Chinese standard
Code-check of bolts according to Hong Kong Code
Code-check of bolts and preloaded bolts according to Hong Kong Code
Code-check of bolts according to Indian standard
Code-check of preloaded bolts according to Indian standards
Code-check of bolts and preloaded bolts according to Russian standards
The forces in bolts, including prying forces, are determined by finite element analysis. The bolt resistances are checked by code provisions. Structural design of bolted steel connections.
SteelKnowledge baseConnectionCBFEMBolts

Code-check of bolts and preloaded bolts (EN)

This article is also available in
ENCZDEESFRITPTNLHUROKRPLTHTRVIZH

Bolts

The initial stiffness and design resistance of bolts in shear are in CBFEM modeled according to Cl. 3.6 and 6.3.2 in EN 1993-1-8. The spring representing bearing and tension has a bi-linear force-deformation behavior with an initial stiffness and design resistance according to Cl. 3.6 and 6.3.2 in EN 1993-1-8.

Design tension resistance of bolt (EN 1993-1-8 – Table 3.4):

Ft,Rd=0.9fubAs/γM2F_{t,Rd}=0.9 f_{ub} A_s / \gamma_{M2}Ft,Rd​=0.9fub​As​/γM2​

Design punching shear resistance of bolt head or nut (EN 1993-1-8 – Table 3.4):

Bp,Rd=0.6πdmtpfu/γM2B_{p,Rd} = 0.6 \pi d_m t_p f_u / \gamma_{M2}Bp,Rd​=0.6πdm​tp​fu​/γM2​

Design shear resistance per one shear plane (EN 1993-1-8 – Table 3.4):

Fv,Rd=αvfubAs/γM2F_{v,Rd} = \alpha_v f_{ub} A_s / \gamma_{M2}Fv,Rd​=αv​fub​As​/γM2​

Design shear resistance can be multiplied by reduction factor βp if packing is present (EN 1993-1-8 – Cl. 3.6.1. (12)), and this option is selected in Code setup.

Design bearing resistance of plate (EN 1993-1-8 – Table 3.4):

Fb,Rd=k1αbfudt/γM2F_{b,Rd} = k_1 \alpha_b f_u d t / \gamma_{M2}Fb,Rd​=k1​αb​fu​dt/γM2​    for standard holes

Fb,Rd=0.6k1αbfudt/γM2F_{b,Rd} = 0.6 k_1 \alpha_b f_u d t / \gamma_{M2}Fb,Rd​=0.6k1​αb​fu​dt/γM2​    for slotted holes

Utilization in tension [%]:

Utt=Ft,Edmin⁡(Ft,Rd, Bp,Rd)Ut_t = \frac{F_{t,Ed}}{\min (F_{t,Rd},\, B_{p,Rd})}Utt​=min(Ft,Rd​,Bp,Rd​)Ft,Ed​​

Utilization in shear [%]:

Uts=Fv,Edmin⁡(Fv,Rd, Fb,Rd)Ut_s = \frac{F_{v,Ed}}{\min (F_{v,Rd},\, F_{b,Rd})}Uts​=min(Fv,Rd​,Fb,Rd​)Fv,Ed​​

Interaction in shear and tension [%]:

Utts=Fv,EdFv,Rd+Ft,Ed1.4Ft,RdUt_{ts}=\frac{F_{v,Ed}}{F_{v,Rd}}+\frac{F_{t,Ed}}{1.4 F_{t,Rd}}Utts​=Fv,Rd​Fv,Ed​​+1.4Ft,Rd​Ft,Ed​​

where:

  • As – tensile stress area of the bolt
  • fub – ultimate tensile strength of the bolt
  • dm – mean of the across points and across flats dimensions of the bolt head or the nut, whichever is smaller
  • d – bolt diameter
  • tp – plate thickness under the bolt head/nut
  • fu – ultimate steel strength
  • αv = 0.6 for grades 4.6, 5.6, 8.8 and 0.5 for grades 4.8, 5.8, 6.8, 10.9
  • k1=min⁡{2.8e2d0−1.7, 1.4p2d0−1.7, 2.5}k_1 = \min \left \{2.8 \frac{e_2}{d_0}-1.7, \, 1.4 \frac{p_2}{d_0}-1.7, \, 2.5 \right \}k1​=min{2.8d0​e2​​−1.7,1.4d0​p2​​−1.7,2.5} – factor from Table 3.4
  • αb=1.0\alpha_b = 1.0αb​=1.0 if the bearing check with αb\alpha_bαb​ is deactivated in Code setup; if the check is activated, the value of αb is determined according to EN 1993-1-8 – Table 3.4: αb=min⁡{αd, fubfu, 1.0}\alpha_b = \min \left \{ \alpha_d, \, \frac{f_{ub}}{f_u}, \, 1.0 \right \}αb​=min{αd​,fu​fub​​,1.0}
  • αd=min⁡{e13d0, p13d0−14}\alpha_d = \min \left \{ \frac{e_1}{3 d_0}, \, \frac{p_1}{3 d_0}-\frac{1}{4} \right \}αd​=min{3d0​e1​​,3d0​p1​​−41​}
  • e1, e2 – edge distances in the direction of the load and perpendicular to the load
  • p1, p2 – bolt pitches in the direction of the load and perpendicular to the load
  • Ft,Ed – design tensile force in bolt
  • Fv,Ed – design shear force in bolt
  • γM2 – safety factor (EN 1993-1-8 – Table 2.1; editable in Code setup)

Edge distances used for bolt bearing resistance must be relevant for general plate geometries, plates with openings, cutouts, etc.

The algorithm reads the real direction of the resulting shear force vector in a given bolt and then calculates the distances needed for the bearing check.

The end (e1) and edge (e2) distances are determined by dividing the plate contour into three segments. The "end segment" is indicated by a 60° range in the direction of the force vector. The "edge segments" are defined by two 65° ranges perpendicular to the force vector. The shortest distance between a bolt and an edge in the relevant segment is then taken as an end, or edge distance.

The algorithm evaluates all plates connected by the bolt—the connecting plates (e.g., a splice plate), the member plates (e.g., a top flange), and the shortest distance is used.

Bolt bearing distances (EN)

The spacing distances between bolt holes (p1; p2) are determined by virtually enlarging the surrounding bolt holes by half their diameter, then drawing two lines in the direction and perpendicular to the shear force vector. When these lines intersect with virtually enlarged bolt holes, then the distances to these bolts are considered as p1 and p2 in the calculation.

If the lines don't intersect with the visually closest bolt (even though the line misses the bolt closely), this bolt is neglected. If the lines don't intersect with any bolt, an infinite value is used.

Bolt bearing distances (EN)

Bolts connecting thin-walled plates

Bolts connecting plates thinner than 3 mm, the provisions of EN 1993-1-3, Table 8.4 are used instead. 

Bearing resistance:

Fb,Rd=2.5⋅αb⋅kt⋅fu⋅d⋅t/γM2F_{b,Rd}=2.5\cdot \alpha_b \cdot k_t \cdot f_u \cdot d \cdot t /\gamma_{M2}Fb,Rd​=2.5⋅αb​⋅kt​⋅fu​⋅d⋅t/γM2​

where:

  • αb=min⁡{1.0,e1/(3d)}\alpha_b=\min \left \{ 1.0, e_1/(3d) \right \}αb​=min{1.0,e1​/(3d)}
  • kt=(0.8t+1.5)/2.5k_t = (0.8 t+1.5)/2.5kt​=(0.8t+1.5)/2.5 for 0.75 mm ≤t≤\le t \le≤t≤ 1.25 mm; kt=1.0k_t=1.0kt​=1.0 for t>1.25t>1.25t>1.25 mm
  • fuf_ufu​ – ultimate strength of the connected plate
  • ddd – bolt diameter
  • ttt – thickness of the connected plate
  • γM2\gamma_{M2}γM2​ – partial safety factor for connections editable in Code setup; by default γM2=1.25\gamma_{M2}=1.25γM2​=1.25

Shear resistance, tension resistance, interaction of tension and shear, and punching shear resistance are determined according to EN 1993-1-8 – the same way as bolts connecting plates with a thickness higher than 3 mm.

Range of validity:

e1≥1.0d0e_1 \ge 1.0 d_0e1​≥1.0d0​

p1≥3d0p_1 \ge 3 d_0p1​≥3d0​

e2≥1.5d0e_2 \ge 1.5 d_0e2​≥1.5d0​

p2≥3d0p_2 \ge 3 d_0p2​≥3d0​

fu≤550 MPaf_u \le 550 \textrm{ MPa}fu​≤550 MPa

3 mm>t≥0.75 mm3 \textrm{ mm} > t \ge 0.75 \textrm{ mm}3 mm>t≥0.75 mm

Minimum bolt size: M6 – checked as d≥6d \ge 6d≥6 mm

Bolt strength grades: 4.6 – 10.9 – checked as fu≤1000f_u \le 1000fu​≤1000 MPa

The bolts will be marked as failing if they are outside the range of validity.

Preloaded bolts

Design slip resistance per bolt grade 8.8 or 10.9 (EN 1993-1-8, Cl. 3.9 – Equation 3.8):

Fs,Rd=ksnμ(Fp,C−0.8Ft,Ed)γM3F_{s,Rd} =\frac{k_s n \mu (F_{p,C} - 0.8 F_{t,Ed})}{\gamma_{M3}}Fs,Rd​=γM3​ks​nμ(Fp,C​−0.8Ft,Ed​)​

The preload (EN 1993-1-8 – Equation 3.7)

Fp,C = 0.7 fub As

The preloading force factor 0.7 can be modified in Code setup.

Utilization [%]:

Uts=VFs,RdUt_s = \frac{V}{F_{s,Rd}}Uts​=Fs,Rd​V​

where:

  • As – tensile stress area of the bolt
  • fub – ultimate tensile strength
  • ks – a coefficient (EN 1993-1-8 – Table 3.6; ks = 1 for normal round holes, ks = 0.63 for slotted holes)
  • μ – slip factor editable in Code setup (EN 1993-1-8 – Table 3.7)
  • n – number of the friction surfaces. Check is calculated for each friction surface separately
  • γM3 – safety factor (EN 1993-1-8 – Table 2.1; editable in Code setup – recommended values are 1.25 for ultimate limit state and 1.1 for serviceability limit state design)
  • V – design shear force in bolt
  • Ft,Ed – design tensile force in bolt

If slip of preloaded bolts is checked for serviceability limit state, they should be afterward switched to "bearing – tension/shear interaction" and checked for the ultimate limit state.

Fire design

Preloaded bolts are assumed to slip, so that the checks of bearing bolts and preloaded bolts are the same.

Checks at fire and at ambient temperature are both performed and the minimum is selected as a design load resistance.

At elevated temperature, bolts are checked according to EN 1993-1-2, Annex D. Note that the area reduced by threads is always used in shear check according to D1.1.1.  

Detailing

Detailing checks of bolts are performed if the option is selected in Code setup. Dimensions from bolt center to plate edges and between bolts are checked. Edge distance e = 1.2 and spacing between bolts p = 2.2 are recommended in Table 3.3 in EN 1993-1-8. User can modify both values in Code setup.

Minimum plate thickness of plates connected by bolts is checked. Plate thickness must be higher than 0.75 mm according to EN 1993-1-3 – Table 8.4.

Information is issued if ductility and rotation capacity requirements for bolted connection in tension according to EN 1993-1-8 – 6.4.2 are not met. If bolt is loaded predominantly in tension, the thinner connected plate should satisfy:

t≤0,36dfubfyt \le 0,36d \sqrt{\frac{f_{ub}}{f_y}}t≤0,36dfy​fub​​​

The default sizes of bolt assemblies are according to EN ISO 4014 – Hexagon bolt heads, EN ISO 4032 – Hexagon regular nuts, and EN ISO 7089 – Plain washers – Normal series – Product grade A. 

Take the latest version of IDEA StatiCa for a test drive today

Get 14 days of full access, completely free.

Check out IDEA StatiCa for free

Related articles

Fillet welds are checked according to EN 1993-1-8. The strength of butt welds is assumed the same as the base metal and is not checked. IDEA StatiCa - structural engineering design software for modeling welded connections.
  • Steel
  • Connection
  • CBFEM
  • Welds
  • EN (Eurocode)
  • +5
  • Steel
  • Connection
  • CBFEM
  • Welds
  • EN (Eurocode)

Knowledge base

Code-check of welds (EN)

Read more
Structural design and code-check of anchors according to Eurocode. The forces in anchors, including prying forces, are determined by finite element analysis, but the resistances are checked using code provisions of EN 1992-4.
  • Steel
  • Connection
  • Anchoring
  • CBFEM
  • Steel-to-concrete
  • EN (Eurocode)
  • +6
  • Steel
  • Connection
  • Anchoring
  • CBFEM
  • Steel-to-concrete
  • EN (Eurocode)

Knowledge base

Code-check of anchors (EN)

Read more
How to define pre-loaded bolts
  • Steel
  • Connection
  • AISC (USA)
  • Bolts
  • Contacts
  • EN (Eurocode)
  • +6
  • Steel
  • Connection
  • AISC (USA)
  • Bolts
  • Contacts
  • EN (Eurocode)

Knowledge base

How to define preloaded bolts

Read more
Workflows for preloaded bolts
  • Steel
  • SLS
  • Connection
  • Bolts
  • +4
  • Steel
  • SLS
  • Connection
  • Bolts

Webinar

Summer Series - Workflows for preloaded bolts

Read more