Idea Statica
  • Steel
  • Concrete
  • BIM & Workflows
  • Support & Learning
  • Pricing
  • Company
  • Steel overview
  • Connection design
  • Member design
  • Parametric design
  • Steel case studies
  • Concrete overview
  • Walls and D-regions
  • Anchoring design
  • Concrete case studies
  • BIM Overview
  • Supported integrations
  • Checkbot
  • Viewer
  • APIs
  • Support Center
  • E-learning & certification
  • Blog
  • Downloads & Licensing
  • Plans
  • Free community tool
  • Enterprise customers
  • Students & educators
  • How much will you save?
  • About us
  • Contact
  • Research & development
  • Authorized resellers
  • Meet our customers
  • Career
  • Steel
    Steel overviewConnection designMember designParametric designSteel case studies
  • Concrete
    Concrete overviewWalls and D-regionsAnchoring designConcrete case studies
  • BIM & Workflows
    BIM OverviewSupported integrationsCheckbotViewerAPIs
  • Support & Learning
    Support CenterE-learning & certificationBlogDownloads & Licensing
  • Pricing
    PlansFree community toolEnterprise customersStudents & educatorsHow much will you save?
  • Company
    About usContactResearch & developmentAuthorized resellersMeet our customersCareer
14-Day Trial
14-Day Trial

Subscribe to our newsletter

Company

  • About us
  • Partners
  • Careers
  • Patent

Resources

  • Customer projects
  • Case studies
  • Connection Library
  • Verification books

Legal

  • EULA
  • Global privacy policy
  • California Privacy
  • TOS Viewer
  • Licensing

Help

  • Contact
  • Quote request
  • Resellers
  • Downloads
FacebookInstagramLinkedInYouTube

Ā© IDEA StatiCa 2009-2026

Trusted and used worldwide by engineers, fabricators & consultants.

Support CenterKnowledge Base ArticlesCode-check of bolts and preloaded bolts according to Hong Kong Code
Advanced analysis types for your steel structures
Bolts are too close to plate edge
Traffic lights for forces in bolts
Prying and high tension force in bolts
Bolt force distribution in end-plate beam-to-column connection
Bolt shear force calculated per shear plane
Through-bolts in hollow sections: design them as pins, not bolts
Bolt bearing distances for Eurocode
Warnings for welds and bolts connecting the same plates
Slip resistance check update according to SP 16
Detailing improvements for bolts and welds in Eurocode
Angle to the grain of the steel-to-timber connections
Filler plate (packing plate) recognition
Smooth results with precise meshing
Code-check of bolts and preloaded bolts (EN)
Code-check of bolts and preloaded bolts (AISC)
Code-check of bolts and preloaded bolts according to Canadian standards
Code-check of bolts and preloaded bolts according to Australian standards
Code-check of bolts and preloaded bolts according to Chinese standard
Code-check of bolts according to Hong Kong Code
Code-check of bolts and preloaded bolts according to Hong Kong Code
Code-check of bolts according to Indian standard
Code-check of preloaded bolts according to Indian standards
Code-check of bolts and preloaded bolts according to Russian standards
Preloaded bolts are checked for shear slip capacity and combination of tension and shear. Structural design of bolted steel connections.
Connection designSteelKnowledge baseHKG (Hong Kong)Connection

Code-check of bolts and preloaded bolts according to Hong Kong Code

This article is also available in
ENCZDEESFRITPTNLHUROKRPLTHTRVIZH

Preloaded bolts are checked for shear slip capacity and combination of tension and shear.

Shear capacity

Shear capacity of preloaded bolts is determined according to Cl. 9.3.6.2 as:

PSL=0.9ā‹…Ks⋅μ⋅P0P_{SL} = 0.9 \cdot K_s \cdot \mu \cdot P_0PSL​=0.9ā‹…Ks​⋅μ⋅P0​

where:

  • KsK_sKs​ – hole coefficient taken as
    • for standard holes Ks=1.0K_s = 1.0Ks​=1.0
    • for oversized holes Ks=0.85K_s = 0.85Ks​=0.85
    • for slotted holes Ks=0.7K_s = 0.7Ks​=0.7
  • μ\muμ – slip factor between connected parts from Table 9.7; editable in Code setup
  • P0P_0P0​ – minimum proof loads of bolts specified in relevant international or local standards

Combined tension and shear

Combined tension and shear is checked according to Cl. 9.3.8.2 as:

FsPSL+Ftot0.9ā‹…P0≤1.0\frac{F_s}{P_{SL}}+\frac{F_{tot}}{0.9\cdot P_0} \le 1.0PSL​Fs​​+0.9ā‹…P0​Ftot​​≤1.0

where:

  • FsF_sFs​ – shear force in a bolt
  • PSLP_{SL}PSL​ – slip resistance of a preloaded bolt
  • FtotF_{tot}Ftot​ – total applied tension in the bolt including the prying force
  • P0P_0P0​ – specified minimum proof load of a preloaded bolt

Related articles

Bolts are checked for shear, bearing, tension capacity, and for combined tension and shear. Structural design of bolted steel connections.
  • Steel
  • Connection
  • HKG (Hong Kong)
  • Bolts
  • CBFEM
  • +5
  • Steel
  • Connection
  • HKG (Hong Kong)
  • Bolts
  • CBFEM

Knowledge base

Code-check of bolts according to Hong Kong Code

Read more
The average stress on a base plate area in contact with concrete is checked against the concrete bearing resistance. IDEA StatiCa - concrete design software for structural code-check of concrete constructions.
  • Steel
  • HKG (Hong Kong)
  • Connection
  • CBFEM
  • Concrete block
  • +5
  • Steel
  • HKG (Hong Kong)
  • Connection
  • CBFEM
  • Concrete block

Knowledge base

Code-check of concrete block according to Hong Kong Code

Read more
How to define pre-loaded bolts
  • Steel
  • Connection
  • AISC (USA)
  • Bolts
  • Contacts
  • EN (Eurocode)
  • +6
  • Steel
  • Connection
  • AISC (USA)
  • Bolts
  • Contacts
  • EN (Eurocode)

Knowledge base

How to define preloaded bolts

Read more
Workflows for preloaded bolts
  • Steel
  • SLS
  • Connection
  • Bolts
  • +4
  • Steel
  • SLS
  • Connection
  • Bolts

Webinar

Summer Series - Workflows for preloaded bolts

Read more