Idea Statica
  • Steel
  • Concrete
  • BIM & Workflows
  • Support & Learning
  • Pricing
  • Company
  • Steel overview
  • Connection design
  • Member design
  • Parametric design
  • Steel case studies
  • Concrete overview
  • Walls and D-regions
  • Anchoring design
  • Concrete case studies
  • BIM Overview
  • Supported integrations
  • Checkbot
  • Viewer
  • APIs
  • Support Center
  • E-learning & certification
  • Blog
  • Downloads & Licensing
  • Plans
  • Free community tool
  • Enterprise customers
  • Students & educators
  • How much will you save?
  • About us
  • Contact
  • Research & development
  • Authorized resellers
  • Meet our customers
  • Career
  • Steel
    Steel overviewConnection designMember designParametric designSteel case studies
  • Concrete
    Concrete overviewWalls and D-regionsAnchoring designConcrete case studies
  • BIM & Workflows
    BIM OverviewSupported integrationsCheckbotViewerAPIs
  • Support & Learning
    Support CenterE-learning & certificationBlogDownloads & Licensing
  • Pricing
    PlansFree community toolEnterprise customersStudents & educatorsHow much will you save?
  • Company
    About usContactResearch & developmentAuthorized resellersMeet our customersCareer
14-Day Trial
14-Day Trial

Subscribe to our newsletter

Company

  • About us
  • Partners
  • Careers
  • Patent

Resources

  • Customer projects
  • Case studies
  • Connection Library
  • Verification books

Legal

  • EULA
  • Global privacy policy
  • California Privacy
  • TOS Viewer
  • Licensing

Help

  • Contact
  • Quote request
  • Resellers
  • Downloads
FacebookInstagramLinkedInYouTube

© IDEA StatiCa 2009-2026

Trusted and used worldwide by engineers, fabricators & consultants.

Support CenterKnowledge Base ArticlesWhy the check for fatigue or brittle failure is not performed?
Non-linear creep in Beam application
Why the check for fatigue or brittle failure is not performed?
Limited interaction check in Beam and RCS
Why the check for fatigue or brittle failure is not performed?
ConcreteReinforced concretePrestressed concreteKnowledge baseBeam

Why the check for fatigue or brittle failure is not performed?

This article is also available in
ENCZDEESFRITPTNLHUROKRPLTHTRVIZH

The necessity for a brittle failure check is to work under EN 1992-2 code and to check the checkbox in the Data tab (BIM, Beam, …) or Calculation control (RCS). Moreover, the brittle failure check is done for quasi-permanent combination, therefore there must be one defined in extreme.

Fatigue check requires having it switched on already in Project data (mainly in RCS) or set appropriate national annex (for instance NN). Another requirement is to set relevant load cases as fatigue types. This load case will be included in the combination, which evaluation needs to be set as ULS Fatigue. After this setup, the check of fatigue should be performed correctly.

Take the latest version of IDEA StatiCa for a test drive today

Get 14 days of full access, completely free.

Check out IDEA StatiCa for free

Related articles

Fatigue check
  • Concrete
  • EN (Eurocode)
  • RCS
  • Fatigue
  • +4
  • Concrete
  • EN (Eurocode)
  • RCS
  • Fatigue

Knowledge base

Fatigue check

Read more
What does "To design position" mean?
  • Concrete
  • EN (Eurocode)
  • Deflections
  • Beam
  • Support
  • +5
  • Concrete
  • EN (Eurocode)
  • Deflections
  • Beam
  • Support

Knowledge base

What does "To design position" mean?

Read more
How to turn on the calculation of non-linear creep
  • Concrete
  • Beam
  • EN (Eurocode)
  • Prestressing losses
  • Reinforcement
  • ULS
  • SIA (Switzerland)
  • +7
  • Concrete
  • Beam
  • EN (Eurocode)
  • Prestressing losses
  • Reinforcement
  • ULS
  • SIA (Switzerland)

Knowledge base

Non-linear creep in Beam application

Read more
How to work with imported internal forces
  • Concrete
  • Beam
  • EN (Eurocode)
  • TDA
  • SCIA Engineer
  • Load effects
  • +6
  • Concrete
  • Beam
  • EN (Eurocode)
  • TDA
  • SCIA Engineer
  • Load effects

Knowledge base

How to work with imported user-defined internal forces

Read more