Rotational capacity limited by bolt and weld failure (Stiffness analysis)

This article is also available in:

In the older versions, the rotational capacity of the connection in the stiffness analysis was determined by 15% plastic strain of plates only.

Newly, the limit is defined by these three factors:

  • Failure of bolts (bolt steel failures in tension and shear)
  • Failure of welds
  • Plates (15% plastic strain)

This affects the Rotational capacity value Φc.

Rotational capacity limited by bolt and weld failure

Available in Expert and Enhanced edition.