Idea Statica
  • Steel
  • Concrete
  • BIM & workflows
  • Support & Learning
  • Pricing
  • Company
  • Steel overview
  • Connection design
  • Member design
  • Parametric design
  • Steel case studies
  • Concrete overview
  • Walls and D-regions
  • Anchoring design
  • Members & cross-sections
  • Concrete case studies
  • BIM overview
  • Supported integrations
  • Checkbot
  • Viewer
  • APIs
  • Support Center
  • E-learning & certification
  • Blog
  • Downloads & Licensing
  • Plans
  • Free community tool
  • Enterprise customers
  • Students & educators
  • How much will you save?
  • About us
  • Contact
  • Research & development
  • Authorized resellers
  • Meet our customers
  • Career
  • Steel
    Steel overviewConnection designMember designParametric designSteel case studies
  • Concrete
    Concrete overviewWalls and D-regionsAnchoring designMembers & cross-sectionsConcrete case studies
  • BIM & workflows
    BIM overviewSupported integrationsCheckbotViewerAPIs
  • Support & Learning
    Support CenterE-learning & certificationBlogDownloads & Licensing
  • Pricing
    PlansFree community toolEnterprise customersStudents & educatorsHow much will you save?
  • Company
    About usContactResearch & developmentAuthorized resellersMeet our customersCareer
14-Day Trial
14-Day Trial
  • Steel
  • Concrete
  • BIM & workflows
  • Support & Learning
  • Pricing
  • Company

Subscribe to our newsletter

Company

  • About us
  • Partners
  • Careers
  • Patent

Resources

  • Customer projects
  • Case studies
  • Connection Library
  • Verification books

Legal

  • EULA
  • Privacy policy
  • California Privacy
  • TOS Viewer
  • Licensing

Help

  • Contact
  • Quote request
  • Resellers
  • Downloads
FacebookInstagramLinkedInYouTube

© IDEA StatiCa 2009-2026

Trusted and used worldwide by engineers, fabricators & consultants.

Support CenterKnowledge Base ArticlesClassification according to stiffness for Indian standard
Advanced analysis types for your steel structures
Stiffness analysis
Connection stiffness and its use in global analysis
How to put rotational stiffness into your FEA model
Why is the capacity different for stress/strain and stiffness analyses?
Export of moment-rotation curve to CSV and DXF
Rotational capacity limited by bolt and weld failure (Stiffness analysis)
Stiffness analysis and deformation capacity of steel joints
Joint classification according to Australian standards
Classification according to stiffness for Indian standard
Joint classification according to Chinese standard
Classification according to stiffness for Hong Kong Code
Joint classification according to Russian standards
The joints are classified according to their moment stiffness according to Eurocode. IDEA StatiCa - structural design of welded and bolted steel connections.
SteelConnection designKnowledge baseIS (India)CBFEM

Classification according to stiffness for Indian standard

This article is also available in
ENCZDEESFRITPTNLHUROKRPLTHTRVIZH

Joints are classified according to their moment stiffness according to Eurocode.

Joints are classified according to joint stiffness to:

  • Rigid – joints with insignificant change of original angles between members,
  • Semirigid – joints which are assumed to have the capacity to furnish a dependable and known degree of flexural restraint,
  • Pinned – joints that do not develop bending moments.

Joints are classified according to the EN 1993-1-8 – Cl. 5.2.2.

  • Rigid – Sj,iniLbEIb≥kb\frac{S_{j,ini} L_b}{E I_b} \ge k_bEIb​Sj,ini​Lb​​≥kb​
  • Semirigid – 0.5<Sj,iniLbEIb<kb0.5 < \frac{S_{j,ini} L_b}{E I_b} < k_b0.5<EIb​Sj,ini​Lb​​<kb​
  • Pinned – Sj,iniLbEIb≤0.5\frac{S_{j,ini} L_b}{E I_b} \le 0.5EIb​Sj,ini​Lb​​≤0.5

where:

  • Sj,ini – initial stiffness of the joint; the joint stiffness is assumed linear up to the 2/3 of Mj,Rd
  • Lb – theoretical length of the analyzed member; set in member properties
  • E – Young's modulus of elasticity
  • Ib – moment of inertia of the analyzed member
  • kb = 8 for frames where the bracing system reduces the horizontal displacement by at least 80 %; kb = 25 for other frames, provided that in every storey Kb/Kc ≥ 0.1. The value of kb = 25 is used unless the user sets "braced system" in Code setup.
  • Mj,Rd – joint design moment resistance
  • Kb = Ib / Lb
  • Kc = Ic / Lc

Related articles

Check steel components according to IS 800 (Indian standards). Structural design of welded and bolted steel connections and steel beam to column connection details.
  • Steel
  • IS (India)
  • CBFEM
  • Connection
  • +4
  • Steel
  • IS (India)
  • CBFEM
  • Connection

Theoretical background

Check of steel connection components (IS 800)

Read more
Capacity design is a part of the seismic check and ensures that the joint has sufficient deformation capacity. IDEA StatiCa - engineering software for the structural design of steel connections and beams.
  • Steel
  • IS (India)
  • CBFEM
  • Seismicity
  • Connection
  • +5
  • Steel
  • IS (India)
  • CBFEM
  • Seismicity
  • Connection

Knowledge base

Capacity design according to Indian Standard

Read more
IDEA StatiCa Connection – Structural design of steel connections
  • Steel
  • Connection
  • EN (Eurocode)
  • AISC (USA)
  • AS (Australia)
  • CSA (Canada)
  • IS (India)
  • GB (China)
  • HKG (Hong Kong)
  • SP 16 (Russia)
  • CBFEM
  • +11
  • Steel
  • Connection
  • EN (Eurocode)
  • AISC (USA)
  • AS (Australia)
  • CSA (Canada)
  • IS (India)
  • GB (China)
  • HKG (Hong Kong)
  • SP 16 (Russia)
  • CBFEM

Theoretical background

IDEA StatiCa Connection – Structural design of steel connections

Read more