Idea Statica
  • Steel
  • Concrete
  • BIM & Workflows
  • Support & Learning
  • Pricing
  • Company
  • Steel overview
  • Connection design
  • Member design
  • Parametric design
  • Steel case studies
  • Concrete overview
  • Walls and D-regions
  • Anchoring design
  • Concrete case studies
  • BIM Overview
  • Supported integrations
  • Checkbot
  • Viewer
  • APIs
  • Support Center
  • E-learning & certification
  • Blog
  • Downloads & Licensing
  • Plans
  • Free community tool
  • Enterprise customers
  • Students & educators
  • How much will you save?
  • About us
  • Contact
  • Research & development
  • Authorized resellers
  • Meet our customers
  • Career
  • Steel
    Steel overviewConnection designMember designParametric designSteel case studies
  • Concrete
    Concrete overviewWalls and D-regionsAnchoring designConcrete case studies
  • BIM & Workflows
    BIM OverviewSupported integrationsCheckbotViewerAPIs
  • Support & Learning
    Support CenterE-learning & certificationBlogDownloads & Licensing
  • Pricing
    PlansFree community toolEnterprise customersStudents & educatorsHow much will you save?
  • Company
    About usContactResearch & developmentAuthorized resellersMeet our customersCareer
14-Day Trial
14-Day Trial

Subscribe to our newsletter

Company

  • About us
  • Partners
  • Careers
  • Patent

Resources

  • Customer projects
  • Case studies
  • Connection Library
  • Verification books

Legal

  • EULA
  • Global privacy policy
  • California Privacy
  • TOS Viewer
  • Licensing

Help

  • Contact
  • Quote request
  • Resellers
  • Downloads
FacebookInstagramLinkedInYouTube

© IDEA StatiCa 2009-2026

Trusted and used worldwide by engineers, fabricators & consultants.

Support CenterVerification examplesBenchmark study of a bolted flange plate moment connection (AISC)
Benchmark study of a bolted flange plate moment connection (AISC)
SteelConnection designVerificationsConnectionAISC (USA)

Benchmark study of a bolted flange plate moment connection (AISC)

This article is also available in
ENCZDEESFRITPTNLHUROKRPLTHTRVIZH

This study performed at the University of Chile presents the results of the verification of a Bolted Flange Plate (BFP) fully restrained moment connection. It compares the hand calculations according to AISC 360-16 with CBFEM in IDEA StatiCa Connection.

A detailed hand calculation is provided for one benchmark example and then 14 more variations are investigated. For each case, the governing failure mode and bending resistance is provided. Next, the fillet welds are replaced by butt welds for all cases to reveal additional failure modes.

The resistance provided by CBFEM is generally in good agreement with AISC 360-16. The resistance of fillet welds provided by CBFEM is conservative compared to AISC when welding to unstiffened column flanges.

Open in ViewerDownload

Prepared by:

Nicolás Leiva, Research Assistant

Ricardo Herrera Mardones, Ph. D., Associate Professor

Department of Civil Engineering, Universidad de Chile

Attached Downloads

  • Benchmark study of a bolted flange plate moment connection.pdf (PDF, 554 KB)