Idea Statica
  • Steel
  • Concrete
  • BIM & workflows
  • Support & Learning
  • Pricing
  • Company
  • Steel overview
  • Connection design
  • Member design
  • Parametric design
  • Steel case studies
  • Concrete overview
  • Walls and D-regions
  • Anchoring design
  • Members & cross-sections
  • Concrete case studies
  • BIM overview
  • Supported integrations
  • Checkbot
  • Viewer
  • APIs
  • Support Center
  • E-learning & certification
  • Blog
  • Downloads & Licensing
  • Plans
  • Free community tool
  • Enterprise customers
  • Students & educators
  • How much will you save?
  • About us
  • Contact
  • Research & development
  • Authorized resellers
  • Meet our customers
  • Career
  • Steel
    Steel overviewConnection designMember designParametric designSteel case studies
  • Concrete
    Concrete overviewWalls and D-regionsAnchoring designMembers & cross-sectionsConcrete case studies
  • BIM & workflows
    BIM overviewSupported integrationsCheckbotViewerAPIs
  • Support & Learning
    Support CenterE-learning & certificationBlogDownloads & Licensing
  • Pricing
    PlansFree community toolEnterprise customersStudents & educatorsHow much will you save?
  • Company
    About usContactResearch & developmentAuthorized resellersMeet our customersCareer
14-Day Trial
14-Day Trial
  • Steel
  • Concrete
  • BIM & workflows
  • Support & Learning
  • Pricing
  • Company

Subscribe to our newsletter

Company

  • About us
  • Partners
  • Careers
  • Patent

Resources

  • Customer projects
  • Case studies
  • Connection Library
  • Verification books

Legal

  • EULA
  • Privacy policy
  • California Privacy
  • TOS Viewer
  • Licensing

Help

  • Contact
  • Quote request
  • Resellers
  • Downloads
FacebookInstagramLinkedInYouTube

© IDEA StatiCa 2009-2026

Trusted and used worldwide by engineers, fabricators & consultants.

Support CenterKnowledge Base ArticlesUS-driven improvements
US-driven improvements
SteelConnection designKnowledge baseACI (USA)AISC (USA)

US-driven improvements

This article is also available in
ENCZDEESFRITPTNLHUROKRPLTHTRVIZH

We have focused on our US users and made their life easier with a set of localization improvements.

Available in Expert and Enhanced edition.

Design codes

Possibility to select desired version of AISC 360 (LRFD & ASD) – bolt assemblies affected. Available standards:

  • LRFD (AISC 360-16)
  • ASD (AISC 360-16)
  • LRFD (AISC 360-10)
  • ASD (AISC 360-10)

The LRFD/ASD differences are already covered.

The differences between AISC 360-10 and 360-16 bolts are marked red:

Table 1: Bolt grade A325

Bolt grade A325M is the same in all codes – yield strength = 660 MPa, tensile strength = 830 MPa

Table 2: Bolt grade A325: Minimum bolt pretension (Table J3.1)

Table 3: Nominal hole dimensions for standard bolts (Table J3.3)

US-specific materials added

The new grade for anchors:

  • ASTM F1554

New MPRL items:

  • ASTM A1043(M), Gr. 36
  • ASTM A1043(M), Gr. 50
  • ASTM A1065, Gr. 50
  • ASTM A1085(M), Gr. A
  • A500, Gr. B, Round
  • A500, Gr. B, Shaped
  • A500, Gr. C, Round
  • A500, Gr. C, Shaped

Capacity design: User-defined Cpr

In the analysis of capacity design, the user may set his/her own value of Cpr (the factor to account for peak connection strength, including strain hardening, local restraint, additional reinforcement, and other connection conditions).

To input a custom value of Cpr, uncheck the “Cpr calculated” option and define the user value.

Top of steel input

The new version brings the possibility to define the bolt spacing and dimensions of several operations with a “top of steel” reference: Cleat, Fin plate, End plate, Splice, Stub and Plate to plate.

AISC & EN seismic templates

A brand-new class of connections is in the New project wizard. You can find here the predefined designs designated for capacity design check (seismic templates).

Based on the selected standards, different templates are displayed. There are twenty-nine templates according to ANSI/AISC 358-18 and eight templates according to EC8.

Imperial unit input

Users working in imperial units will appreciate the implementation of the established format of dimensions. From now on, the following number format are accepted:

Examples:     2'-0"3/4, 2-0"3/4, 2-3/4, 3/4 [in,ft]   for Imperial format

                             1, -1, 15, 0.75 [in,ft]                              for Decimal format

For bolts, you are now able to define the transverse and longitudinal spacing, which is more understandable than the previous input method. The numerical format for bolts is

Examples:     2"2/3 3" or 2"2/3;3" [in,ft]     for Imperial format

                      0.15 0.12 or 0.15;0.12 [in,ft] for Decimal format

The first coordinate represents the first bolt to be placed, the position of the other can be defined either relative to the first one (space separator) or in an absolute manner (semicolon separator).

Related articles

IDEA Statica Version 21.0
  • Concrete
  • Steel
  • Connection
  • Detail 2D
  • Member
  • Checkbot
  • Viewer
  • RCS
  • ACI (USA)
  • AISC (USA)
  • EN (Eurocode)
  • BIM link
  • Advance Steel
  • Tekla Structures
  • SAP2000
  • SCIA Engineer
  • STAAD.Pro
  • Revit
  • Robot Structural Analysis
  • Advance Design
  • AxisVM
  • ETABS
  • midas Civil + Gen
  • RFEM
  • RSTAB
  • +25
  • Concrete
  • Steel
  • Connection
  • Detail 2D
  • Member
  • Checkbot
  • Viewer
  • RCS
  • ACI (USA)
  • AISC (USA)
  • EN (Eurocode)
  • BIM link
  • Advance Steel
  • Tekla Structures
  • SAP2000
  • SCIA Engineer
  • STAAD.Pro
  • Revit
  • Robot Structural Analysis
  • Advance Design
  • AxisVM
  • ETABS
  • midas Civil + Gen
  • RFEM
  • RSTAB

Release notes

Release notes IDEA StatiCa Steel & Concrete 21.0

Read more