Idea Statica
  • Steel
  • Concrete
  • BIM & Workflows
  • Support & Learning
  • Pricing
  • Company
  • Steel overview
  • Connection design
  • Member design
  • Parametric design
  • Steel case studies
  • Concrete overview
  • Walls and D-regions
  • Anchoring design
  • Concrete case studies
  • BIM Overview
  • Supported integrations
  • Checkbot
  • Viewer
  • APIs
  • Support Center
  • E-learning & certification
  • Blog
  • Downloads & Licensing
  • Plans
  • Free community tool
  • Enterprise customers
  • Students & educators
  • How much will you save?
  • About us
  • Contact
  • Research & development
  • Authorized resellers
  • Meet our customers
  • Career
  • Steel
    Steel overviewConnection designMember designParametric designSteel case studies
  • Concrete
    Concrete overviewWalls and D-regionsAnchoring designConcrete case studies
  • BIM & Workflows
    BIM OverviewSupported integrationsCheckbotViewerAPIs
  • Support & Learning
    Support CenterE-learning & certificationBlogDownloads & Licensing
  • Pricing
    PlansFree community toolEnterprise customersStudents & educatorsHow much will you save?
  • Company
    About usContactResearch & developmentAuthorized resellersMeet our customersCareer
14-Day Trial
14-Day Trial

Subscribe to our newsletter

Company

  • About us
  • Partners
  • Careers
  • Patent

Resources

  • Customer projects
  • Case studies
  • Connection Library
  • Verification books

Legal

  • EULA
  • Global privacy policy
  • California Privacy
  • TOS Viewer
  • Licensing

Help

  • Contact
  • Quote request
  • Resellers
  • Downloads
FacebookInstagramLinkedInYouTube

© IDEA StatiCa 2009-2026

Trusted and used worldwide by engineers, fabricators & consultants.

Support CenterKnowledge Base ArticlesBuckling of gusset plates
Advanced analysis types for your steel structures
Global buckling vs. local buckling. What does it mean?
Number of buckling modes
Buckling factor shows negative value
Buckling of gusset plates
Steel joint buckling analysis
Linear Buckling Analysis (LBA)
Buckling analysis (EN)
Buckling analysis according to AISC
Buckling of gusset plates
SteelConnection designMember designKnowledge baseConnection

Buckling of gusset plates

This article is also available in
ENCZDEESFRITPTNLHUROKRPLTHTRVIZH

Engineers generally want to avoid buckling of gusset plates prior to buckling of connected members. Linear buckling analysis is not reliable when investigating buckling failure mode. A general procedure to obtain buckling resistance is described in this article.

The best approach to determine the buckling resistance of a subsystem consisting of joint-member-joint is to use GMNIA (geometrically and materially nonlinear analysis with imperfections) in IDEA StatiCa Member application. 

IDEA StatiCa Connection lacks the context of surrounding structure. Furthermore, geometrical nonlinearity is used only for joints of hollow sections and imperfections cannot be set. Linear buckling analysis provides a factor – a multiplier of set loads to reach bifurcation point of a perfect, elastic structure. Real structure will usually buckle under smaller load, and it is unclear what factor limit should be used for linear buckling analysis of gusset plates, i.e. a factor above which buckling is not a concern anymore. 

Eurocode EN 1993-1-1 provides general recommendation:

αcr≤15 for plastic analysis\alpha_{cr} \le 15 \textrm{ for plastic analysis}αcr​≤15 for plastic analysis

AISC 360-22 in Chapter J4.4 provides similar limit:

Lc/r≤25L_c/r \le 25Lc​/r≤25

Which may be translated to a limit of αcr\alpha_{cr}αcr​ that depends on yield strength and the safest limit is 12.7 for A36 steel grade.

Such limits are very high. Factors below these limits should trigger a warning and a buckling limit state should be checked. However, αcr\alpha_{cr}αcr​ can hardly be translated into buckling resistance.

Also note that the bolted gusset plate connections provide reasonable buckling factors while connections with pins provide extremely low buckling factors. This is due to the analysis model of pin that consists of many special elements (rigid body elements, beam elements, gap elements...) and provides good results in terms of resistances of pin in shear, bending and bearing. Therefore a simple procedure is described below. 

Buckling resistance check

This simplified buckling resistance check should be performed when buckling factor falls below the limit αcr\alpha_{cr}αcr​ mentioned above.

  • Model type of member connected by gusset plate should be set to N-Vy-Vz.
  • Forces in should be set to Bolts.
  • Add a fictive shear force acting in the center of bolts or pin that bends the gusset plate with the magnitude of 1/10 of compressive force: Vz=N/10V_z=N/10Vz​=N/10.
  • Calculate materially nonlinear analysis. 

The fictive force takes into account any eccentricities caused by imperfections and geometrical nonlinearity. Validation to experiments is in the linked article.

Take the latest version of IDEA StatiCa for a test drive today

Get 14 days of full access, completely free.

Check out IDEA StatiCa for free

Related articles

Gusset plate design in IDEA StatiCa Connection
  • Steel
  • Connection
  • AISC (USA)
  • EN (Eurocode)
  • +4
  • Steel