Auto-calculation of self-weight of discontinuity regions

Ez a cikk a következő nyelveken is elérhető
Self-weight of the analyzed structure is from IDEA StatiCa v22.0 considered automatically by the software, so the users don’t have to spend extra time with manual calculation.

The functionality Self-weight is available for all structures modeled as a whole except parts of the beams with trimmed ends. It works similarly to Surface load type, the value of the self-weight is calculated automatically for each part of the structure according to its real thickness. The Self-weight is defined as a Permanent load case.

IDEA StatiCa Auto-calculation of self-weight of discontinuity regions

If the model contains more regions (walls), the self-weight can be defined for each region separately. There are options for assigning the self-weight for a particular region or for all of them at the same time.

IDEA StatiCa Auto-calculation of self-weight of discontinuity regions

Properties such as the direction of gravitation and gravitational constant can be changed in the Settings.

IDEA StatiCa Auto-calculation of self-weight of discontinuity regions

Available in both Enhanced edition of IDEA StatiCa Concrete and IDEA StatiCa Prestressing.

Introduction video of the Self-weight auto-calculation feature:

Kapcsolódó cikkek

Release notes IDEA StatiCa Steel & Concrete 22.0

What is the CSFM?

Can you trust the CSFM?