Sometimes, there are changes to your FEA/BIM model, such as different member section size or loads. These can be synchronized between Checkbot and the FEA/BIM model.

There are two possible alternatives:

  • Synchronize the Current item (if one or more joints are selected)
  • Synchronize the whole imported Structural model
inline image in article

To test this feature, you can change a member section size or shape in your FEA/BIM application or amend a load case or combination etc: change columns to a bigger section. Remember to re-analyze the FEA model.

inline image in article

In Checkbot select the changed members (there may be more than one) and from the Current item panel, select Sync.

inline image in article

The Checkbot project will be updated, member (and connections) design is preserved, but the results will be invalidated. You can see that the column is now updated - matching the change in the FEA model.

inline image in article

Simply code-check the highlighted member again by selecting Calculate from the Current item panel.  Please remember that bigger changes in the model might require additional validation steps with the affected members (as above).

inline image in article

If the members do not give the desired results, then you can open them again to optimize the design (i.e. strengthen if they fail the code-check or lighten if the utilization is too low).