2 Ergebnis für "capacity"
Theoretischer Hintergrund
Capacity design according to AISC
Capacity design is a part of seismic check and ensures that the joint has sufficient deformation capacity. The objective of capacity design is to confirm a building undergoes controlled ductile behavior in order to avoid collapse in a design-level earthquake
Stahl
Connection
CBFEM
Seismicity
AISC (USA)
Theoretischer Hintergrund
Catalog of AISC limit states and design requirements
IDEA StatiCa provides an option to check base metal capacity at the fusion face. This check can be enabled in the “Code setup” window . states “When inelastic finite element analysis is used, peak strains in the thick shell (T × T × T) elements should not exceed 0.02/T at the nominal capacity Welds are stiff and will attract load even when combined with contact but demands from compressive forces will rarely exceed the capacity, even if the
Stahl
CBFEM
Connection
AISC (USA)